AXLE BOGIE (MTVT) REPAIR - Continued
0121 00
ASSEMBLY - Continued
CAUTION
Acceptable bearing backlash is 0.002-0.012 in. (0.05-0.30 mm). Failure to achieve
acceptable bearing backlash may result in damage to equipment.
Housing must rotate by hand without binding. Failure to comply may result in damage
to equipment.
NOTE
Use two pry bars to move housing to move housing on shaft when measuring bearing
backlash.
Record bearing backlash measurement.
15. Measure bearing backlash from frame rail (23) to front side of housing (7).