TM 9-2350-222-10-2
OPERATE UNDER UNUSUAL CONDITIONS (PERFORM SHALLOW WATER FORDING)- Continued
8.
Loosen two mounting screws (E) securing clamps (F)
holding personnel heater exhaust tube (G) to right
front fender. Exhaust tube (G) will slide freely.
9.
Unscrew two nuts and screws and four washers (H)
from elbow (K).
10.
Place exhaust tube (G) in exhaust elbow (K).
11.
Place two nuts and screws and four washers (H) in
clamp (J) and elbow (K). These hold clamp (J) and
exhaust tube (G) to exhaust elbow (K). Tighten
screws and nuts.
TA252872
Change 1 2-666.6