C8, TM 9-2350-230-12
Section 2-3. OPERATION OF AUXILIARY EQUIPMENT
2-4. Operation Instructions
The following tables and illustrations pro-
vide auxiliary equipment operating instruc-
tions.
TABLE 2-6. OPERATION OF MBA3 AIR FILTER UNIT
STEP
PROCEDURE
FIG/ITEM
BEFORE OPERATION
NOTE. The MBA3 air filter unit is used in connection with a tank
protective mask for protection against toxic gases and in extremely
dusty conditions to remove dust from air breathed by crew members.
WARNING: 1. In toxic gas attack, don mask immediately before
beginning operation of filter unit.
2. The air filter unit will not protect user against car-
bon monoxide.
3. Do not supply air from filter unit to masks when
vehicle interior is below +20 degrees. Injury to user's lungs may
result.
1
Perform before-operation preventive-maintenance checks and services
2
Unstrap carriers from stowed positions and remove masks. 2-16/1,2
3
Don masks and adjust face pieces.
4
Remove commander's, gunner's, and loader's air purifier-to-canister 2-16/4
hoses from stowage bag.
5
Remove driver's air purifier-to-canister hose from spring clips and 2-16/8,9
connect to canister.
NOTE. If
the air filter unit is to be
used by
fewer than four persons, 2-16/11
disconnect the unused hose from the air purifier. Cover the unused
outlet or outlets on the air purifier with air flow control caps. When
only three outlets are used, the fourth outlet is covered with an air-
flow control cap without a center hole. When less than three outlets
are used, one of the holes is covered with an airflow control cap with-
out a center hole and the other outlets are covered with airflow control
caps with center holes.
6
Remove spring clip from air purifier housing.
7
Remove caps from air purifier and connect commander's, gunner's, and
loader's air purifier-to-canister hoses.
8
Turn on air filter unit with rheostat knob located on loader's control 3-1/A
box, and increase to maximum airflow. If excessive airflow around
face piece causes discomfort, reduce the flow accordingly with
rheostat knob.
AFTER OPERATION
9
Remove masks, place in carriers and stow.
10
Turn air filter unit COMPLETELY OFF (rheostat knob counterclockwise).
11
Uncouple commander's, gunner's, and loader's air purifier-to-canister
hoses and place in stowage bag.
2-24