C4, TM 9-2350-230-12
Figure 9-108. Removal/installation - bilge pump relays and mount
PRELIMINARY STEP
REMOVAL
1. BACK OFF ADJUSTING NUT AND ADJUSTER (1) TO END OF
ROD
CAUTION: WHEN BELTS ARE TO BE REMOVED, SUPPORT
2. COTTER PIN, WASHER, AND STRAIGHT PIN
3. SCREW (2)
4. BELT TENSIONER
INSTALLATION
REVERSE REMOVAL PROCEDURE. TIGHTEN ADJUSTER (1)
UNTIL SPRING IS FULLY COMPRESSED.
NOTE. TENSIONER IS SELF ADJUSTING. REPLACE BELTS
IF PIN IS WITHIN 1/4 INCH FROM BOTTOMING OUT. WHEN
REPLACING BELTS, ALWAYS REPLACE THE COMPLETE SET OF
FOUR.
WE11036A|
Figure 9-109. Removal/installation - generator "V" belt tensioner
9-115