TM 9-2350-277-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES -- Continued
0090 00
ITEM
INTERVAL
MAN-
ITEM TO BE
CREWMEMBER
EQUIPMENT
NO.
HOUR
CHECKED OR
PROCEDURE
NOT READY/
SERVICED
AVAILABLE
IF:
53
DRIVER
After
Rear Power Plant
Access Panel
CAUTION
Make sure rear power plant access
panel is closed tightly before continuing
your PMCS or operating carrier.
a.
Check rear compartment access panel for
good sealing.
b.
Check panel for damage or warps.
c.
Check panel latches for looseness. Tighten
Latch is
loose latches. Report missing latches to
missing or will
unit maintenance.
not tighten.
d.
cracks, or poor seating.
0090 00-72
Change 4