TM 9-4110-254-14
Table 2-1. Operator Preventive Maintenance Checks and Services - Continued
Location
Item
Interval
Item to Check/
Procedure
Not Fully Mission
No
Service
Capable If:
14
Weekly
Coil
a
Inspect the coil guard and cover panel for
Debris or foreign material
Guard/Cover
any debris or foreign material obstructing the
obstructs the openings.
Panel
openings. Remove any debris or foreign
material from the openings. If debris cannot
be removed, notify unit maintenance to
remove it.
b. Inspect the coil guard and cover panel for
any cracks, tears, and loose or missing
hardware. If cracked, notify direct support
maintenance for repair. If hardware is loose
or missing, notify unit maintenance to
tighten or replace as necessary.
c. Inspect for chipped or missing paint and
evidence of corrosion. If paint is damaged or
shows evidence of corrosion, notify direct
support maintenance to paint it.
a. Inspect the access panels for any debris or
15
Weekly
Access Panels
Debris or foreign material
foreign material obstructing the openings.
obstructs the access panel
Remove any debris or foreign material from
openings.
the access panel openings. If debris cannot
be removed, notify unit maintenance to
remove it.
b. Inspect the access panels for any cracks,
tears, and loose or missing hardware. If
cracked, notify direct support maintenance
for repair. If hardware is loose or missing,
notify unit maintenance to tighten or replace
it as necessary.
c. Inspect for any chipped or missing paint and
evidence of corrosion. If paint is damaged or
access panel shows evidence of corrosion,
notify direct support maintenance to paint it.
Inspect for loose or missing heat shield gasket and
16
Weekly
Heat Shield
for splits or tears. If damaged or loose, notify unit
Gaskets
maintenance to tighten or replace it as necessary.
2-12