TM9-4110-254-14
4-14.
TOP ACCESS PANEL REPLACEMENT.
This task covers.
a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions:
General Safety Instructions:
WARNING
disconnected.
Materials/Parts:
High voltage and exposed rotating parts are
Lock Washers (6) (Each Barrel Bolt Assembly)
used in the refrigerant on unit. Personal injury
can result if power is connected.
a. Removal Remove six bolts (1), lock washers (2), and panel (3). Discard lock washers.
b. Installation. Install panel (3), six new lock washers (2), and bolts (1).
Figure 4-9. Top Panel
NOTE
FOLLOW-ON MAINTENANCE
Connect power and put unit back into service.
4-31