TM 9-4110-254-14
5-3. CONTROL PANEL REPAIR.
This task covers:
Repair
INITIAL SETUP
Materials/Parts.
Equipment Conditions:
Lock Washers (2)
Control box cover door raised and latched.
General Safety Instructions:
Adhesive, General Purpose
WARNING
Wiping Rag
Acetone
Acetone and methyl-ethyl ketone (MEK) are
flammable and their vapors can be explosive.
Methyl- Ethyl Ketone
Repeated or prolonged skin contact or
inhalation of vapors can be toxic. Use in a
Gaskets (2)
well ventilated area, wear gloves, and keep
away from sparks or flame.
Gasket
Repair
(1)
Remove two bolts (I1) and lock washers (2). Open control panel (3). Discard lock washers.
(2)
Remove as much old gasket material (4) or (5) as possible by pulling or scraping it away from the control
panel and operating instruction plate (3).
(3)
Soften and remove old adhesive and gasket (4) or (5), residue, using acetone or methyl-ethyl ketone
(MEK) and a stiff brush
(4)
Be sure that the attaching surface of the control panel (3) is clean and free of paint and old adhesive
material.
(5)
Coat the mating surfaces of the control panel (3) and gasket (4) or (5) with adhesive. Let both surfaces
air dry until adhesive is tacky, but will not stick to fingers
(6)
Starting with an end, carefully press gasket (4) or (5) onto the control panel (3). Press firmly overall to
ensure complete contact.
(7)
Close control panel (3). Install two new lock washers (2) and bolts (1)
5-5