TM 9-4110-256-14
(2) Tag and disconnect wire leads (2).
(3) Remove two self locking nuts (4), flat washers (5), bolts (6), and push switch (3). Discard self locking nuts.
c. Installation.
(1) Install push switch (3), two bolts (6), flat washers (5), and new self locking nuts (4).
NOTE
Smaller diameter sleeving insulation must go over wire lead connecting to push switch terminal
C.
(2) Install insulation sleeving (1) over wire leads (2).
(3) Using tags and wiring diagram (fig. 1-4), connect wire leads (2). Remove tags.
NOTE
Sleeving insulation covers only terminal C on one side of push switch, but must cover both
terminals NO and NC on the other side.
(4) Slip sleeving insulation (1) over exposed terminals and shrink in place using heat gun.
Figure 4-29. Push (Door Switches
NOTE
FOLLOW-ON MAINTENANCE:
Connect power and put unit back into service.
4-73