ARMY TM 9-4120-380-14
NAVY EE-000-BA-MMA-010/7053-AC
AIR FORCE TO 35E9-136-21
4.31 RESISTOR BOARD - Continued
INSTALLATION
a. Position fiber board (4) and resistor board (3) In mounting position
b. Secure with four screws (5), flat washers (2), and four locknuts (l)
c.
Reconnect leads and remove tags
FOLLOW ON PROCEDURES
a
b.
Connect air conditioner Input power at source.
Figure 4-22. Resistor Board
4-64