ARMY TM 9-4120-380-14
NAVY EE-000-BA-MMA-010/7053-AC
AIR FORCE TO 35E9-136-21
4.38 RELAY MOUNTING PLATE. - Continued
REPAIR
NOTE
Repair consists of replacing rivets (2), floating locknuts (1), rivnuts (6,7) or mounting
plate (5).
a
Floating Locknuts.
(1)
Remove two rivets (2) securing floating locknut (1) to mounting plate (5).
(2)
Remove floating locknut (1)
(3)
Position new floating locknut (1) on plate (5) and secure with two rivets (2).
b. Rivnuts
(1)
Remove 6-32 (6) or 10-32 (7) rivnuts
(2)
Install new 6-32 (6) or 10-32 (7) rivnuts.
c.
Relay Mounting Plate If the relay mounting plate is damaged or bent, replace plate (5)
REASSEMBLE
b. Position plate (5) m control box assembly (4) and secure with six screws (3)
FOLLOW ON PROCEDURES
a
b
c
d
e. Connect air conditioner input power at source.
4-79