4.41 TIME DELAY RELAYS (TR1 AND TR2). -Continued
REPAIR/REPLACE
NOTE
Repair consists of replacing defective external resistor (3) or time delay relay (1).
a. Remove defective external resistor (3).
b
Cut resistor leads to 3/4" (1.91 cm).
c
Install shrink tubing.
d
Solder ring terminals to ends of resistor leads.
e. Shrink the tubing.
f
Install new resistor (3) into place.
REMOVAL
Pull relay (1) from socket (2).
INSTALLATION
Plug relay (1) into socket (2).
FOLLOW ON PROCEDURES
a. Install control box assembly (paragraph 4 27).
b. Connect air conditioner input power at source.
4-86