d. Installation.
(1) If valve body (8) was not removed, go to step (9).
(2) Secure valve body (8) to bracket (13) with two screws (14) and two lock washers
(15).
(3) Fit tube ends to valve body (8) and align mounting hardware of bracket (13) to
through holes in casing.
(4) Secure bracket (13) to casing with four screws (11) and four lock nuts (12).
(6) Apply heat sink (Appendix E, item 21) or wrap wet rags around valve body.
(8) Remove heat sink or rags.
(9) Install diaphragm (9) in valve body (8). Be sure pin on diaphragm points toward
coil (4).
(10)
Install O-ring (10) in plunger assembly (7).
(11)
Align through holes in plunger assembly (7) to threaded holes in valve body (8).
(12)
Secure plunger assembly (7) to valve body (8) with two screws (6).
Install coil (4) and nameplate (3) on valve (5).
(13)
(14)
Secure coil (4) to valve (5) with nut (l).
(15)
(16)
Leak test all newly connected joints and those in the repair area (See para. 5-10).
(17)
(18)
Charge the system (See pare. 5-12).
(19)