TM 9-4120-402-14
5-10. SERVICE MANIFOLD INSTALLATION. - continued
Figure 5-5. Service Manifold Installation.
b.
Remove.
(1
Check that unit DISCHARGE and SUCTION SERVICE VALVES are closed.
(2)
Open all four service manifold valves to bleed off pressure.
(3)
Remove hoses from DISCHARGE and SUCTION SERVICE VALVES.
(4)
Close service manifold valves.
(5)
Install protective caps (4) onto DISCHARGE and SUCTION SERVICE VALVES.
(6)
Install access (service valves) cover (3) with four sets of screws (1), and flat washers (2).
NOTE
FOLLOW-ON MAINTENANCE:
Connect power at power source.
5-33