TM 9-4120-402-14
(3)
Remove two screws (5). Remove tube and plunger assembly (6), gasket (7), and diaphragm (8).
(4)
Check valve body (9) for visible damage. Normally valve body replacement is unnecessary. If valve
body is in good condition, skip steps (5) through (7).
(5)
(6)
(7)
Remove two screws (11) and lock washers (12). Remove valve body (9).
(8)
Secure valve body to casing side with two screws (11) and lock washers (12).
(9)
(10) Install diaphragm (8) into valve body (9) and gasket (7) into tube and plunger assembly (6).
(11) Secure tube and plunger assembly (6) to valve body (9) with two screws (5).
(12) Slide coil (3) and data plate (2) onto valve body stem (4). Secure with nut (1).
(13) Using wiring diagram figure 4-10 and tags, connect wire leads to solenoid coil. Remove tags.
NOTE
FOLLOW-ON MAINTENANCE:
5-70