TM 9-4120-403-14
Figure 5-32. Casing Insulation, Condenser Section
Inspection
Check that insulation is not loose, missing, burnt, or otherwise damaged. Replace if missing or damaged. Reglue
if loose.
Repair
(1)
Remove as much old gasket material as possible, by pulling or scraping away from the metal
surface.
(2)
Soften and remove old adhesive and gasket residue, using toluene and a stiff brush.
(3)
Cut replacement gasket to size per dimensions in Appendix F.
(4)
Be sure that the surface to which the gasket is to be applied is clean and free of old adhesive material.
(5) Coat the mating surfaces of the metal and the gasket with adhesive. Let both surfaces air dry until the
adhesive is tacky, but will not stick to fingers.
(6)
Starting with an end, carefully attach the gasket to the metal. Pre s into firm contact all over..
s
Follow-on procedures:
(1)
(2)
5-100