TM 9-4120-404-14
4-9. EVAPORATOR FAN ASSEMBLY. - Continued.
CAUTION
Damage to thermistor on wiring harness may cause the unit to fail. Be very careful
in moving thermistor and thermistor wiring.
(3) Remove two screws (1), two flat washers (2), two lock washers (3), two nuts (4), two clamps (5), and wiring
harness (6) from evaporator fan assembly (7).
(4) Remove two screws (8), two flat washers (9), and two nuts (10).
(5) Remove two screws (11), two lock washers (12), and two scroll ducts (13).
(6) Remove four screws (14) and four flat washers (15) holding evaporator fan assembly (7) to cabinet.
(7) Disconnect evaporator fan motor wires from wiring harness.
(8) Remove evaporator fan assembly (7) from unit.
b. Repair.
Repair is limited to replacement of defective parts.
c. Installation.
(1) Place evaporator fan assembly (7) into unit.
(2) Install four flat washers (15) and four screws (14) to attach the evaporator fan assembly (7) to cabinet.
(3) Install two scroll ducts (13), two lock washers (12), and two screws (11).
(4) Install two nuts (10), two flat washers (9), and two screws (8).
(5) Install wiring harness (6), two clamps (5), two nuts (4), two lock washers (3), two flat washers (2), and two
screws (1) onto evaporator fan assembly (7) frame.
(7) Connect all evaporator fan wires to terminal on cabinet frame and remove tags.
(10) Reconnect air conditioner to power source.
4-20