TM 9-4120-407-14
SECTION VI UNIT MAINTENANCE PROCEDURES
3-11. GENERAL. The procedures in this section have been arranged in the order in which the items appear
in the unit (0) maintenance level column on the Maintenance Allocation Chart (MAC) which is provided in
Appendix 8. Step-by-step procedures have been provided for all action authorized to be performed by Unit
Maintenance in the order in which they appear on the MAC.
Do not operate this unit with the panels/covers, screen/guard, and
grilles removed or open unless the instructions tell you to. When this
is necessary, do so with care to prevent personal injury.
3-12. FABRIC COVER REPLACEMENT.
a. Removal
b. Installation
This task covers:
Service Refrigeration Unit Tool Kit
(Item 1, Appendix 8)
a. Removal.
(1) If fabric cover (1) is rolled up, rotate two turnbutton fasteners (2), lift two straps (3), and roll cover
down
(2) Remove 26 screws (4), flat washers (5), and fabric cover (1).
Figure 3-7. Fabric Cover
b . Installation
(1) Install fabric cover (1) and align the eyelets (6) with the mounting holes (7).
(2) Install 26 screws (4) and flat washers (5).
3-56