TM 9-4910-387-14-1
HOOKUP FOR SUPPLY PUMP TEST
1
HOSE ASSEMBLY -3 (1). Remove
from straight connector (2).
2
STRAIGHT CONNECTOR (2).
Remove.
3
PLUG (MS49005-4) (3). Install.
REMOVAL OF SUPPLY PUMP TEST HOOKUP
2
STRAIGHT CONNECTOR (2). Install.
3
HOSE ASSEMBLY -3 (3). Install on
straight connector (2).
1
PLUG (1). Remove.
2-115