TM 9-4910-663-12
(6) The status of the stand shall be periodically monitored to
insure the condition of the storage location and stand does not
deteriorate.
c. Removal from Administrative Storage. Remove any preservative
materials, install, lubricate and prepare the stand for operation in
accordance with procedures outlined in this TM.
1-4. DESTRUCTION OF ARMY MATERIAL TO PREVENT ENEMY USE. Destruction
of the test stand when subject to capture or abandonment in the combat
zone will be undertaken by the using army only when, in the judgement
of the unit commander concerned, such action is necessary in accord-
ance with orders of, or policy established by, the Army Commander.
Refer to TM 750-244-3 for destruction procedures.
1-5.
QUALITY ASSURANCE/QUALITY CONTROL (QA/QC). No requirement for
pertinent QA/QC instructions.
1-6. REPORTING QUALITY DEFICIENCY REPORT (QDR). QDRs will be pre-
pared on SF 368, Quality Deficiency Report.
Instructions for prepar-
ing QDRs are provided in DA PAM 738-750. QDRs should be mailed
directly to: Commander, U.S. Army Armament, Munitions, and Chemical
Command, ATTN: AMSMC-QAD, Rock Island, IL 61299-6000. A reply will
be furnished directly to you.
Section II.
DESCRIPTION AND DATA
1-7. DESCRIPTION.
The test stand (fig 1-1) is a self-contained unit
used for testing, loading, and measuring the electrical output of
direct-driven or pulley-drive dc generators, voltage regulators, and
ac/dc systems, and for free-run testing of starters. All accessories
required for performance of the various tests described in this publi-
cation are furnished.
1-8.
DATA PLATES.
a. Reversing Switch Caution Plate (1, fig 1-1).
This plate cau-
tions the operator not to operate the reversing switch while the vari-
drive is in motion.
Change 1