Section II. D/S OPERATIONAL TESTS AND PROCEDURES
3-7.
Operational Performance and Test Tables.
Tables 3-8 through 3-21 provide data necessary for performance testing, set tests and maintenance calibration
procedures which can be accomplished on DRAGON Weapon System and DMS items at the D/S or G/S maintenance levels.
3-8.
Table 3-9 provides a
listing of
the DMS-D card calibration requirements. After affecting repair or
replacement of
any
DMS-D cards, refer to table 3-9 for maintenance calibration steps (table 3-10) which must be accomplished.
3-9.
Retest After Repair.
If component parts or printed circuit cards are replaced or repaired during
testing, a complete retest of the UUT is required, unless otherwise noted in the
test procedure.
3-10. Abbreviation Cross Reference.
A complete listing of all non-standard abbreviations used in these procedures is
NOTE
Numbers appearing in triangles
denote fault isolation procedures
appearing at the end of the test procedure being performed.
NOTE
When performing the CORRECTIVE ACTION instructions as shown in the
following example; " eplace card A12. Check A12 pin 120, 11, 12, and
R
89." The following maintenance sequence shall be used:
1. Replace card.
2. Retest, if fault is corrected, restart the performance test as
indicated. If fault is not corrected:
(a) Place card on correct extender card. Refer to table 3-21
for extender card/UUT usage.
(b) Check pins indicated in CORRECTIVE ACTION.
3-50