TM9-4935-481-14-1
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE CORRECTIVE ACTION
STEP
UNIT
PROCEDURE CORRECTIVE ACTION
910
CIP
COUNTER INHIBIT(SEC) dial to 10.49.
920
CIP
RUN/HOLD/OFF switch to HOLD.
911
PPE
Momentarily actuate TEST START switch and observe a reading of
921
CIP
COUNTER INHIBIT(SEC) dial to 1054.
DMM
922
CIP
RUN/HOLD/OFF switch to RUN.
-0.0050 to +0.0050 Vdc for SEQUENCE switch position AUTO 7
923
Repeat steps 915 through 919.
through AUTO 16.
924
CIP
RUN/HOLD/OFF switch to HOLD.
Replace card A7. Check A7
925
CIP
COUNTER INHIBIT(SEC) dial to 10,56.
pin 80.
926
CIP
RUN/HOLD/OFF switch to RUN.
912
CIP
RUN/HOLD/OFF switch to HOLD.
927
DMM
Observe a reading of -0.0050 to +0.0050 Vdc for SEQUENCE switch
913
CIP
COUNTER INHIBIT(SEC) dial to 10.51.
PPE
914
CIP
RUN/HOLD/OFF switch to RUN.
positions AUTO 7 through AUTO 16.
915
PPE
Set SEQUENCE switch to the positions indicated and observe the
Replace card A7. Check A7 pin 80.
DMM reading for each setting.
Vertical Manual
928
PPE
SEQUENCE switch to MNL.
SEQUENCE
Reading
929
MCP
SELECTOR A switch to G14.
930
MCP
SELECTOR B switch to I-23.
916
AUTO 8
-2.428 to -2.452 Vdc
931
MCP
SELECTOR C switch to I-24.
Replace card A7. Check A7 pins
932
DMM
Observe a reading of -8.900 to -9.100 Vdc.
90, 94, 72, 96 and 91.
Replace card A8. Check A8 pins
917
AUTO 9
+2.428 to +2.452 Vdc
59, 117, 15, 13 and 14.
Replace card A7. Check A7 pins
933
RS
Adjust VERT control fully cw.
90, 94, 72, 96 and 91.
934
DMM
Observe a reading of +8.900 to +9.100 Vdc.
918
AUTO 12
-3.085 to -3.115 Vdc
Replace card A8. Check A8 pins
Replace card A7. Check A7 pins
59, 117, 15, 13 and 14.
92, 94, 72, 96 and 91.
935
RS
Adjust VERT control to +5.000 0.050 Vdc.
919
AUTO 13
+3.085 to +3.115 Vdc
DMM
Replace card A7. Check A7 pins
93, 72, 96 and 91.