C3
TM 9-4935-481-14-1
Table 3-14. TTS Performance Test-Continued
Table 3-14. TTS Performance Test-Continued
STEP UNIT
PROCEDURE
CORRECTIVE ACTION
STEP UNIT
PROCEDURE
CORRECTIVE ACTION
352
PPE
Momentarily actuate TEST START switch (power on) and allow test
365
PPE
Momentarily actuate TEST START switch twice (power off, power on)
cycle to complete.
and allow test cycle to complete.
353
PPE
SEQUENCE switch to AUTO 11.
366
TTS
Set MODE switch as indicated and observe appropriate lamp
354
TTS
MODE switch to MISSILE CAD.
illuminated.
355
PPE
Momentarily actuate TEST START switch twice (power off, power on)
and allow test cycle to complete.
SQ TS VE
VP
HE
RIP
WC
IR
FIL
AGC
DG
356
TTS
Set MODE switch as indicated and observe appropriate lamp
illuminated.
N
G --
--
N
N
--
N
G
G
G
SQ TS
VE
VP
HE
RIP
WC
IR
FIL
AGC
DG
367
PPE
Momentarily actuate TEST START switch (power off).
368
PPE
SEQUENCE switch to AUTO 6.
-
N
N
--
N
G
--
N
G
G
G
369
TTS
MODE switch to BORESIGHT.
NOTE
357
MCP
SELECTOR A switch to A13.
Perform steps 370 through 374 within 3.5
358
DMM
Observe a HI reading.
minutes of step 370 initiation.
359
PPE
Momentarily actuate TEST START switch (power off).
360
PPE
SEQUENCE switch to AUTO 6.
370
PPE
Momentarily actuate TEST START switch (power on) and allow test
361
TTS
MODE switch to BORESIGHT.
cycle to complete.
371
PPE
SEQUENCE switch to AUTO 13.
NOTE
372
TTS
MODE switch to MISSILE CND.
Perform steps 362 through 366 within 3.5
373
PPE
Momentarily actuate TEST START switch twice (power off, power on)
minutes of step 362 initiation.
and allow test cycle to complete.
374
TTS
Set MODE switch as indicated and observe appropriate lamp
362
PPE Momentarily actuate TEST START switch (power on) and allow test
illuminated.
cycle to complete.
363
PPE
SEQUENCE switch to AUTO 12.
SQ TS
VE
VP
HE
RIP
WC
IR
FIL
AGC
DG
364
TTS
MODE switch to MISSILE C[D.
N
G
--
--
G
N
--
N
G
G
G