TM9-4935-481-14-1
C4
Table 3-18. MTS Performance Test-Continued
Table 3-18. MTS Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
208
DMM
Observe a reading of +0.2230 to +0.2770 Vdc.
224
MCP
SELECTOR A switch to B4.
(12)
225
MTS
Adjust HORIZ BIAS ADJ control to +2.687 + 0.002 Vdc.
DMM
209
MTS
TARGET RANGE switch to 5.
226
MTS
TRACKER POWER switch to AUTO.
210
DMM
Observe a reading of +0.1730 to +0.2270 Vdc.
227
TP
Momentarily actuate TEST START switch and observe TRIG lamp
(12)
MTS
illuminated, then off; which is followed by TARGET RANGE 1 illuminated then off.
211
MTS
TARGET RANGE switch to 6.
(13) for TRIG
212
DMM
Observe a reading of +0.1400 to +0.1940 Vdc.
(14) for TARGET RANGE 1
(12)
228
MCP
SELECTOR A switch to B6.
213
MTS
TARGET RANGE switch to 7.
229
DMM
Observe a reading of -1.282 to -1.631 Vdc.
214
DMM
Observe a reading of +0.1160 to +0.1700 Vdc.
(15)
(12)
230
MTS
Observe TRACKER INDICATOR SCORE meter vertical needle indicates 77 to 83.
215
MTS
TARGET RANGE switch to 8.
(16)
216
DMM
Observe a reading of +0.0980 to +0.1520 Vdc.
231
MCP
SELECTOR A switch to B3.
(12)
232
DMM
Observe a reading of -1.282 to -1.631 Vdc.
217
MTS
TARGET RANGE switch to 9.
(17)
218
DMM
Observe a reading of +0.0840 to +0.1380 Vdc.
233
MTS
Observe TRACKER INDICATOR SCORE meter horizontal needle indicates 77 to 83.
(12)
(18)
219
MTS
TARGET RANGE switch to 10.
234
MCP
SELECTOR A switch to B7.
220
DMM
Observe a reading of +0.0730 to +0.1270 Vdc.
235
MTS
TARGET RANGE switch to 2.
(12)
236
MTS
TRACKER POWER switch to (R) 1-3.
221
MCP
SELECTOR A switch to B70
237
MTS
Adjust VERT BIAS ADJ control to +1.000 + 0.002 Vdc.
222
MTS
TARGET RANGE switch to 1.
DMM
223
MTS
Adjust VERT BIAS ADJ control to +2.687 + 0.002 Vdc.
DMM
3-284