TM 9-2330-398-10
2-21.
FILTERED FUEL SERVICING OPERATIONS
(continued).
12.
Release nozzle trigger at end of operation and
remove nozzle (18 or 21) from vehicle.
13.
Adjust engine speed to 1000-1200 rpm.
14.
Rewind hose reel (19 or 22). Do not rewind both
hose reels at the same time. Tighten hose reel
lock (17). Drain hose into suitable container.
15.
Close all valves.
16.
WARNING
DO NOT let go of static reel
grounding cable when rewinding until
ball stop is firmly touching reel.
Failure to follow this warning may
cause injury to personnel.
17.
Disconnect static reel grounding wire (16) from
vehicle. Rewind static reel grounding wire (16).
18.
Cover and store fire extinguishers (2).
Close
hose reel cabinet doors.
C.
FUEL SAMPLING
Fuel sampling is done during filtered fuel dispensing
operation. Fuel is removed through an Aqua-Glo probe
and adapter installed on outlet nipple of one or both
meters.
NOTE
Additional
information
on
fuel
sampling may be obtained from FM
10-68.
2-22.
REFUEL ON THE MOVE (ROM) ASSEMBLY AND OPERATING PROCEDURES.
WARNING
Fuel handlers must wear appropriate safety equipment during fueling operations, to avoid injury.
NOTE
Components of the Refuel on the Move (ROM) Assembly (NSN 4730-01-295-1842) are listed in
The M969A2 semi-trailers have ROM capabilities.
Refer to FM 10-71 for instructions on installing, operating, and
disassembling the ROM kit.
2-60