TM 9-4120-411-14
Figure 4-24. Supply Panel.
4.26 ELECTRICAL ASSEMBLY REPLACEMENT.
THIS TASK COVERS:
a. Removal
b. Installation
INITIAL SETUP:
Tools
Materials/Parts
General Mechanics Tool Kit
Lock Washers (qty 3)
Lock Washers (qty 2)
Lock Washers (qty 13)
Marker Tags (qty 76)
Crimp Nuts (qty 14)
Splices (qty 8)
Tiedown Straps (qty 5)
Tiedown Straps (qty 23)
WARNING
Rotating parts and lethal voltage levels are used in operating the FDECU. Be sure
power source is disconnected. Injury or death can occur if connected to power
source.
(1) Shutdown the FDECU per paragraph 2.4 and disconnect it from power source.
4-61