TM 55-1925-285-13&P
0009 00
From Sheet 1
Warning:
Take great care when working around energized
electrical equipment. Contact between
unprotected body parts and electrical conductors
can cause serious injury.
Is
Is
120 Vac
120 Vac
Cable defect between remote
present across
present across
No
Yes
indicator (alarm) assembly and
terminals 1 and 2
terminals 2 and 3
sampling/sensor assembly. Notify
at the alarm PCB
on the power
maintenance supervisor.
(figure 3,
PCB (figure 1,
item 1)?
item 3)?
Yes
No
Replace the power
Replace the remote
PCB (WP 0016 00).
indicator (alarm) assembly
(WP 0015 00).
Exit
Procedure 20. Audible Alarm Inoperative when OCM Is In ALARM Mode (Sheet 2 of 2)
0009 00-30