TM9-2330-207-14
REPLACEMENT
a. 24-Volt Dome Iight Switch (M128 and M129
Series). Remove and install the 24-volt dome light
REMOVE THREE SELF-TAPPING
STEP 1.
SCREWS SECURING SWITCH
PLATE TO WALL.
STEP 2.
PULL SWITCH PLATE FROM WALL
AND REMOVE TWO WIRES FROM
SWITCH.
STEP 3.
REMOVE KNURLED RETAINER
RING SECURING SWITCH TO SWITCH
PLATE AND SEPARATE SWITCH AND
PLATE.
STEP 4.
SECURE SWITCH AND SWITCH PLATE
TOGETHER WITH RETAINER RING
REMOVED IN STEP 3. ABOVE.
STEP 5.
INSTALL WIRES REMOVED IN STEP 2
ABOVE.
STEP 6.
SECURE SWITCH PLATE TO WALL
WITH THREE SCREWS REMOVED
IN STEP 1 ABOVE.