TM 9-2330-246-14
4-25. 208-VOLT POWER ENTRY PANEL AND COVER REPLACEMENT (M348A2H).
This Task Covers:
Installation
c.
a.
Removal
b.
Cleaning and Inspection
Initial Setup:
Materials/Parts:
Equipment Conditions:
208-volt power entry panel connectors removed
Z Dry cleaning solvent (Item 13, Appendix E)
Power entry panel terminal boards removed from
One gasket
Two weatherstrips
Tools/Test Equipment:
Five retaining rings
Z General mechanic's tool kit
Fifty-five rivets
Drill bit set
Electric drill
q Rivet gun
REMOVAL
a.
1.
Remove five cover-locking screws (24) and flatwashers (23) from cover plate (26) and panel assembly (15).
Remove eight rivets (1) securing hinge (2) to panel assembly(15). Remove hinge and cover plate (26). Discard
2.
rivets.
Remove weatherstrip (3) from hinge (2). Discard weatherstrip.
3.
Remove eight rivets (27) securing hinge (2) to cover plate (26). Remove hinge. Discard rivets.
4.
Remove eight rivets (19) securing each hinge (4) to cover plate (26). Remove hinges and shields (5) from cover.
5.
Discard rivets.
Remove rivet (7) securing brace (8) to each shield (5). Discard rivets.
6.
Remove seven rivets (6) securing each hinge (4) to shield (5). Remove hinges from shields. Discard rivets.
7.
Remove gasket (21) from cover plate (26). Discard gasket.
8.
Remove wingnut (20) from bolt (25). Remove bolt from cover plate (26).
9.
Remove 16 screws (18) and panel assembly (15) from semitrailer.
10.
Remove weatherstrip (11) from panel assembly (15). Discard weatherstrip.
11.
Remove wingnut (10) from each bolt (9). Remove two bolts from panel assembly (15).
12.
Remove five retaining rings (22) and nuts (14) from panel assembly (15). Discard retaining rings.
13.
Remove three screws (17) from each hook (16). Remove three hooks from semitrailer.
14.
From inside semitrailer, remove 26 screws (12) and cover assembly (13).
15.
4-42