TM 9-2330-246-14
4-105. TERMINAL ENTRANCE ASSEMBLY REPLACEMENT (M348A2F) (Con't).
If captive screw (17) is damaged, remove retain-
9.
ing ring (19) from captive screw mounted on
shields (16). Remove captive screw and flatwash-
er (18). Discard retaining ring.
8
CLEANING AND INSPECTION
b.
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
The solvent's flash point is 10OF-138F (38C-59C). If you become dizzy while
using cleaning solvent, immediately get fresh air and medical help. If solvent contacts
eyes, immediately wash your eyes and get medical aid.
1.
Clean all parts with dry cleaning solvent and dry thoroughly. Ensure that bonding surfaces on cover, hinge, and
semitrailer for gaskets, coated cloth, and frame are clean and dry.
2.
Inspect cover and frame for warpage and distortion. Straighten if necessary.
Inspect hinge for straightness and deterioration. Replace hinge if damaged.
3.
4.
Inspect shields mounted on cover for warpage and distortion, If shields cannot be straightened, replace cover.
Inspect bracket (20) mounted on cover (10) for warpage and distortion. If bracket cannot be straightened,
5.
replace cover.
Inspect all other parts for defects and damage. Replace defective and damaged parts.
6.
INSTALLATION
c.
1.
If removed, install captive screw (17) and flatwasher (18) in shields (1 6) and secure with new retaining ring (19).
If removed, install captive screw (8) and flatwasher (9) in cover (10) and secure with new retaining ring (11).
2.
Install clip (6) on cover (10) using two new rivets (7). From inside of cover, peen rivets so that they are flush.
3.
Install three nuts (14) in frame (l).
4.
TA700332
4-251