TM9-2330-358-14&P
(3) Tag and disconnect six wires from terminal boards and white ground wire
from nose box cover (3).
(4) Remove four bolts (5), washers (6) and nuts (7) that secure 24 volt
receptacle (8) to cover (3).
(5) Withdraw receptacle (8).
Figure 4-3.
24 Volt Receptacle
b.
Disassembly.
(1) Unscrew grommet retaining nut (1, fig. 4-4) and slide back on cable
assembly (2).
(2) Slide grommet (3) on cable assembly (2).
(3) Using removal and installation tool from electrical connector repair kit,
pull inserts (4) forward out of receptacle assembly grommet (7).
(4) Using soldering gun, heat solder well and remove pins (4) from wire end
(5).
(5) Tag wires with letters on face of the grommet (3).
(6) Pull wires (6) out of grommet (3) and nut (1).
c.
Assembly.
(1) Slide retaining nut (1) on wire with threads (6) facing outward.
(2) Put wire ends (6) into back of grommet (3). Make sure that the wires (6)
are matched with the proper pin letters on grommet (3).
4-23