TM 9-2330-371-14&P
HYDRAULIC TUBES AND FITTINGS - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
INSTALLATION - CONTINUED
Right tube
a.
Wrap fitting two turns counterclockwise
T-fitting (1)
16.
fitting (2)
with teflon tape.
b.
Put in and tighten using 7/16-inch
wrench.
If replacing T-fitting only, go to
step 22.
Three tube
Put on and squeeze together.
Tube (3)
17.
clamps (4)
Nut (7) and
Put on and tighten using 9/16-inch wrench.
Axle (5) and
18.
Iockwasher (8)
stud (6)
Two nuts (10) and
Put on and tighten using 7/16-inch wrench.
Axle (5) and two
19.
Iockwashers (11)
studs (9)
Tube (3) and
a.
Wrap fitting two turns counterclockwise
Right connecting
20.
fitting (13)
with teflon tape.
fitting (12)
b.
Put in and tighten using 7/16-inch
wrench.
If replacing right hydraulic tube
only, go to follow-on maintenance.
Hose fitting (15)
a.
Wrap hose fitting two turns counter-
Master
21.
clockwise with teflon tape.
cylinder (14)
b. Put in and tighten using 5/8-inch
wrench.
Swivel
a.
Wrap connector two turns counterclock-
T-fitting (1) and
22.
connector (17)
wise with teflon tape.
hose (16)
b.
Put in and tighten using 5/8-inch
wrench and 1/2-inch wrench.
4-82