TM 9-2330-394-13&P
MECHANICAL STOP AND RESILIENT MOUNT REPLACEMENT
0076 00
- Continued
RESILIENT MOUNT REMOVAL, LMTVT
NOTE
Left and right side resilient mounts are removed the same way. Right side shown.
Remove bolt (9) and resilient mount (8) from leaf spring plate (10).
RESILIENT MOUNT INSTALLATION, LMTVT
NOTE
Left and right side resilient mounts are installed the same way. Right side shown.
1.
Position resilient mount (8) on leaf spring plate (10) with bolt (9).
Tighten bolt (9) to 77-94 lb-ft (104-127 Nm).
2.
END OF WORK PACKAGE
0076 00-5/6 Blank