TM 9-2350-277-10
ASSEMBLY AND PREPARATION FOR USE MORTAR FIRE
CONTROL SYSTEM (MFCS), M95 ONLY
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Maintenance Level
References
Operator
TM 9-1015-250-10
TM 9-1220-248-10
Personnel Required
Gunner
Assistant Gunner
INSTALLATION OF MFCS EQUIPMENT
CAUTION
The Mortar Fire Control System (MFCS) is not intended for ground-mounted use. If mortar is
to be employed in the ground-mounted mode, the pointing device (PD) and the PD mounting
bracket MUST be removed.
To avoid equipment damage, always install dust cover/protective cap on cable and line
replacement unit (LRU) connectors, as necessary.
CAUTION
Ensure power is turned off at power distribution assembly (PDA) before components are
installed, to prevent damage to equipment.
CAUTION
To prevent equipment damage, do not handle computer by cable connecting keyboard to
display area.
NOTE
Perform Steps 1 - 19 prior to mission if commander's interface (CI), gunner's display (GD),
pointing device (PD), precision lightweight GPS receiver (PLGR) or defense advanced GPS
receiver (DAGR), and driver's display (DD) are not in place in M1064A3 carrier.
Change 4