TM 9-4110-256-14
SECTION II DIRECT SUPPORT MAINTENANCE PROCEDURES
5-2.
CONTROL PANEL COVER REPAIR.
This task covers: a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions:
Tools:
Brush
Materials/Parts:
General Safety Instructions:
General Purpose Adhesive
WARNING
Wiping Rag
Acetone and methyl-ethyl ketone (MEK)
Acetone
are flammable and their vapors can be
explosive. Repeated or prolonged skin
Methyl-Ethyl Ketone
contact or inhalation of vapors can be
toxic. Use in a well ventilated area,
Gaskets (2)
wear gloves, and keep away from
sparks or flame.
Gasket
Gasket
Repair.
NOTE
Repair is limited to replacement of gasket material.
(1) Remove as much old gasket material (1), (2), or (3) as possible by pulling or scraping it away from the control
panel cover (4).
Figure 5-1. Control panel Cover.
5-3