(8) Install new fused cluster seal (35), new fused cluster terminal (34), and three screws (33).
(9) Install terminal box (32) and four screws (31).
(10) Install new valve plate gasket (9), two reed valves (8), valve plate assembly (7), new cylinder head gasket
(6), cylinder head (5), and eight screws (4).
(11) Check compressor lubricating oil level at sight glass (42). Level should be at mid-point of sight glass. Add
or remove oil as necessary.
(a) Remove plug (52).
(b) Add or remove oil as necessary.
(c) Wrap anti-seize tape around plug (52) threads.
(d) Install plug (52).
e. Installation.
(1) Install two service valves (21) onto tubing (22) with mounting surfaces at right angles to each other and
WARNING
Compressor weight exceeds 400 lb (181 kg). Use appropriate lifting device to avoid personal
injury.
(2) Install compressor (3).
(3) Carefully lift each comer of compressor (3) and install one each mounting spring (29) and shipping bracket
(30).
(4) Install four mounting spacers (28), flat washers (27), screws (26), and new locknuts (25).
(5) Install suction screen (24), two new service valve gaskets (23), service valves (21), and four screws (20).
(6) Wrap anti-seize tape around threaded end of coupling (18). Install one cap and chain (19) onto each
(7) Wrap anti-seize tape around threaded end of each tee (17) and install three tees.
(8) Aline capillary tubes (15) with tees (17) using tags as reference being careful not to bend or kink tubes.
Tighten five flare nuts (16).
(9) Install strain relief cable bushing (13) and conduit locknut (14).
(10) Push wire leads (11) through strain relief cable bushing (13). Install wire leads, using tags and wiring