TM9-4935-481-14-1
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
SEQUENCE
Reading
SEQUENCE
Reading
861
AUTO 4
+4.706 to +4.754 Vdc
Replace card A7. Check A7
871
AUTO 11
+7.43 to +7.538 Vdc
pins 83, 102, 63, 64, 66 and 70.
(117)
862
CIP
COUNTER INHIBIT(SEC) dial to 10.49.
872
CIP
RUN/HOLD/OFF switch to HOLD.
863
PPE
Momentarily actuate TEST START switch and observe a reading of
873
CIP
COUNTER INHIB (SEC) dial to 10.54.
DMM
874
CIP
RUN/HOLD/OFF switch to RUN.
-0.0050 to +0.0050 Vdc for SEQUENCE switch positions AUTO 7
875
Repeat steps 867 through 872.
through AUTO 16.
876
CIP
RUN/HOLD/OFF switch to HOLD.
Replace card A7. Check A7
877
CIP
COUNTER INHIBIT(SEC) dial to 10.56.
pins 83, 91, 65, 66 and 67.
878
CIP
RUN/HOLD/OFF switch to RUN.
864
CIP
RUN/HOLD/OFF switch to HOLD.
879
DMM
Observe a reading of -0.0050 to +0.0050 Vdc for PPE
865
CIP
COUNTER INHIBIT(SEC) dial to 10.51.
SEQUENCE switch positions AUTO 7 through AUTO 16. Leave switch in position AUTO 16.
866
CIP
RUN/HOLD/OFF switch to RUN.
Replace card A7. Check
867
PPE
Set SEQUENCE switch to the positions indicated and observe the
A7 pins 83, 63 and 62.
DMM reading for each switch setting.
880
CIP
RUN/HOLD/OFF switch to HOLD.
881
CIP
COUNTER INHIBIT(SEC) dial to 17.69.
SEQUENCE
Reading
882
CIP
RUN/HOLD/OFF switch to RUN.
868
AUTO 8
-5.970 to -6.030 Vdc
883
DMM
Observe a reading of -0.0050 t +0.0050 Vdc.
(114)
(118)
869
AUTO 9
+5.970 to +6.030 Vdc
884
CIP
RUN/HOLD/OFF switch to HOLD.
(115)
885
CIP
COUNTER INHIBIT(SEC) dial to 17.74.
886
CIP
RUN/HOLD/OFF switch to RUN
870
AUTO 10
-7.43 to -7.538 Vdc
(116)
3-109