TM 55-1925-282-14&P
0009 00
Product Water is Too Salty
At the applicable flow control
panel with the system operating:
1. Fully OPEN the system operation
pressure valve.
2. Observe the flow meters
Do the
product water
Perform
No
and brine flow meters
procedure 4 in
combined readings equal
this work package.
4.2 gal (15.9 L)
per minute?
Yes
Does the
product water
Yes
flow meter indicate that
the system is exceeding
maximum
output?
Replace the RO
No
Operate the
ROWPU at normal
system operation
pressure.
At the
applicable
Salinity probe is
system controller,
Yes
defective. Refer to
does the salinity meter
direct support
indicate an acceptable
maintenance for
salinity reading?
repair.
No
water diverter valve is
defective. Refer to direct
support maintenance for
repair.
Exit
Procedure 5. Product Water is too Salty
END OF WORK PACKAGE
0009 00-900-9 lank
0 9 /10 b