TM 55-1925-282-14&P
0009 00
B
From Sheet 1
WARNING:
Take great care
when working around
energized electrical
equipment. Contact
between unprotected
body parts and
electrical conductors
can cause serious
injury or death.
A From Sheet 1
Open the applicable
system controller cover,
and check for the
Does
presence of 24 Vdc
Verify that the
the fresh
at the INPUT 24Vdc (-)
24 Vdc battery
No
water flush
and (+) terminals.
charger is ON,
pump operate for a
and allow the
complete flush
battery to fully
cycle?
charge.
Is
24 Vdc
Notify the
Yes
Yes
Isolate and repair
present and
No
maintenance
the 24 Vdc
available to the
supervisor of
distribution fault.
system
the defect.
controller?
While
flushing, do
the brine flow meters
Yes
indicate a combined
flow rate of about
4 gal (15.1 L) per
minute?
No
Yes
Service the fresh
While
While
water flush pump
flushing, do
flushing, do
inlet strainer
Service the
Yes
the brine flow meters
the brine flow meters
No
charcoal
indicate a combined
indicate a combined
Check for and
filters
flow rate of about
flow rate of about
remove blockages
4 gal (15.1 L) per
4 gal (15.1 L) per
or kinks in the fresh
minute?
minute?
water flush piping.
No
Replace the
faulty fresh water
flush pump
Exit
Procedure 3. No Fresh Water Flow During Fresh Water Flush Cycle (Sheet 2 of 2)
0009 00-7