TM 55-1925-284-14&P
0006 00
Table 1. Valve Alignment for MSD Operation Under Unusual Conditions
Item Number
Valve
Function
Position During Operation
(Figure 3)
Number
Under Unusual Conditions
1
CA-80
COV-LP AIR
CLOSED
2
CA-81
COV-LP AIR
CLOSED
3
CA-82
LP AIR HOSE SHUTOFF
CLOSED
4
CA-83
PRV-SET AT 2 PSIG
Factory Set
5
CA-84
RV-SET AT 3 PSIG
Factory Set
6
MSD-3
POTW FILL TO MSD ISLN
CLOSED
7
MSD-5
BLOWER DISCHARGE SHUTOFF
CLOSED
8
MSD-6
BLOWER DISCH TO AIR SCOURING
CLOSED
SOV
9
MSD-8
MEDIA TANK PUMP-OUT DR
CLOSED
10
MSD-9
MEDIA TANK DRAIN
CLOSED
11
MSD-10
WET WELL DISCHARGE
CLOSED
12
MSD-11
WET WELL SAMPLE
CLOSED
13
MSD-13
WET WELL DRAIN TO HOLDING TANK
CLOSED
14
MSD-14
MSD DISCH PUMP GAGE ISLN
CLOSED
15
PD-4
WASTE WTR TO SEW HLDG TANK
OPEN
16
PW-100
POTW ISOLATION
CLOSED
17
SD-1
SEWAGE INLET TO MSD
CLOSED
18
SD-2
SEWAGE OVERBOARD DISCHARGE
CLOSED
19
SD-3
SEWAGE DRAIN TO HOLDING TANK
CLOSED
20
SD-4
COV-SEW DISCH PMP NO. 2 SUCT
CLOSED
21
SD-5
COV-SEW DISCH PMP NO. 1 SUCT
CLOSED
22
SD-6
COV-SEW DISCH PMP NO. 2 DISCH
CLOSED
23
SD-7
COV-SEW DISCH PMP NO. 1 DISCH
CLOSED
24
SD-8
SEWAGE OVERBOARD DISCHARGE
CLOSED
25
SD-9
SEWAGE TO SHORE CONN
CLOSED
0006 00-3