TM 55-1925-285-13&P
0005 00
2. Set to ON the OILY WATER SEPARATOR circuit breaker (figure 2, item 1) in the 120V distribution panel No. 4.
The green POWER AVAILABLE indicator (figure 1, item 3) will illuminate to indicate that the OWS control panel
has power available.
3. Align the OWS, the Oily Bilge (OB), and OCM valves as indicated in table 1 and figure 3.
4. If the OWS and the system inlet piping are not completely filled with water, purge all air from the system by
performing a manual backflush, as described in WP 0006 00.
! CAUTION
The OCM will operate regardless of fluid flow through the monitor when the OCM OPERA-
TION SELECTOR Switch A1S1 is in the TEST position. Operating the OCM without flow
through it for more than 2 minutes will result in damage to the OCM. Failure to comply
with this caution will result in damage to the equipment.
5. Set the OCM OPERATION SELECTOR Switch A1S1 (figure 4, item 1) to the OFF position.
1
2
Figure 2. 120V Distribution Panel No. 4
0005 00-2