TM 55-1925-285-13&P
0005 00
3
5
4
ALARM LIMIT
OPERATION
(PPM) SELECTOR
SELECTOR
AUTO
70 PPM
REMOTE
OFF
15 PPM
TEST
1
2
Figure 4. Sampling/Sensor Assembly Interior
6. Set the OIL CONTENT MONITOR circuit breaker (figure 2, item 2) in the 120V distribution panel No. 4 to ON.
The red indicator (figure 5, item 1) on the OCM diverter valve position indicator (figure 5, item 2) will illuminate
to signal that the OCM has power available.
NOTE
With the OPERATION SELECTOR Switch A1S1 in the AUTO position, the OCM will not
operate until the pressure switch senses a pressure between 5 to 25 PSI (0.3 to 1.7 bar)
at the OCM sample inlet. The OCM will automatically shut down if the pressure at the
OCM sample inlet falls below 5 PSI (0.3 bar).
7. Position the OPERATION SELECTOR Switch A1S1 (figure 4, item 1) to AUTO.
0005 00-5