TM 55-1925-285-13&P
0009 00
From Sheet 2
Measure the dc voltage between
the terminal points and GND on
the PCB assembly (figure 1, item 4).
Is the
measurement
No
Replace the power PCB
between +5 Vdc
assembly (WP 0016 00).
and -5 Vdc at
all points?
Yes
Notify the
Exit
maintenance
supervisor.
Procedure 11. OCM POWER ON Indicator Does Not Light (Sheet 3 of 3)
0009 00-17