TM 55-1925-285-13&P
0009 00
OCM WARNING 3
(Red LED) Lit
of the OCM (WP 0018 00).
Can the
OCM be
No
Notify maintenance
calibrated
supervisor.
properly?
Yes
Take a sample from the
OCM drain. Examine
the sample.
Is the
Pump the OWT to a shore
Yes
water darker
facility and take steps to
than light
prevent dirt (solids) from
tea?
entering the OWS.
No
Is there
Check for air leaks in the
a high level
Yes
OWS discharge or nozzle
of air bubbles
sampler. Tighten all pipe
in the sample
and valve seals.
water?
No
Pump the OWT to a shore
Are there
Yes
facility and use only approved
suds in the
detergents in the bilge
sample?
No
Replace the processor
PCB and SDA as a
Exit
matched, calibrated
assembly (WP 0016 00).
Procedure 14. OCM WARNING 3 (Red LED) Lit
0009 00-21