OWS Discharge is Diverted Inboard When
OCM Detects Less Than Alarm Limit
Warning:
Take great care when working around energized
electrical equipment. Contact between
unprotected body parts and electrical conductors
can cause serious injury.
Is
120 Vac
Diverter valve is defective.
No
present at the
Notify maintenance
diverter
supervisor.
valve?
Yes
are in the first B position
(figure 2, item 1) and second
A position (figure 2, item 2).
Are the
Does the
jumpers
No
diverter valve
Correctly install
installed
operate
Yes
correctly?
properly?
Yes
No
Warning:
Take great care when working around energized
electrical equipment. Contact between
unprotected body parts and electrical conductors
can cause serious injury.
Check for 120 Vac across
terminals 2-4, 2-6, and 2-7 of
the power PCB (figure 1, item 3)
when in ALARM.
Warning:
Take great care when working around energized
electrical equipment. Contact between
unprotected body parts and electrical conductors
can cause serious injury.
Is
Yes
Replace the power
120 Vac
PCB (WP 0016 00).
present?
No
Notify the maintenance
Exit
supervisor of the defect.
Procedure 17. OWS Discharge Is Diverted Inboard When OCM Detects Less Than Alarm Limit