TM 55-1925-286-13&P
0005 00
1
3
TO PUMP
DRIVE ENGINE
2
TO BOW
THRUSTER ENGINE
Figure 6. Ship's Service Air System Valve Locations (Forward Bulkhead)
4. Check that valve CA-48 SVCE AIR TK DR (figure 1, item 14) is CLOSED.
5. Activate the control air system by completing the following actions:
a. Align air dryer piping and valves by completing the following actions:
(1)
OPEN the air dryer inlet valve (figure 7, item 1).
(2)
OPEN the air dryer outlet valve (figure 7, item 2).
(3)
Open the transducer valve (figure 7, item 3).
(4)
OPEN the filter valve (figure 7, item 4).
(5)
CLOSE the bypass valve (figure 7, item 5).
4
5
1
AIR DRYER
FROM
AIR
RECEIVER
2
TO
TRANSDUCER
3
Figure 7. Control Air Dryer Valve Locations