TM 55-1925-286-13&P
0016 00
5. Remove the wiring (figure 2, item 5) from the coil (figure 2, item 4).
6. Remove the drain pipe (figure 2, item 6) from the drain valve assembly (figure 3, item 1).
7. Inspect the drain valve assembly (figure 3, item 1) and remove any foreign material.
8. If damage to the drain valve assembly (figure 3, item 1) is found, replace the drain valve assembly
(WP 0017 00). If no
damage is
noted, continue with the procedure.
1
Figure 3. Drain Valve Assembly
ASSEMBLY
1. Install the drain pipe (figure 2, item 6) into the drain valve assembly (figure 3, item 1).
2. Install the wiring (figure 2, item 5) to the coil (figure 2, item 4).
3. Install the solenoid (figure 2, item 3), observing the flow direction noted during disassembly.
4. Secure the solenoid coil (figure 2, item 4) to the solenoid (figure 2, item 3) with the nut (figure 2, item 2).
5. Install the cover (figure 1, item 2) and secure it with the four screws (figure 1, item 1).
6. Remove the lockouts and tagouts (FM 55-502).
8. Press the manual override switch (figure 2, item 7) and observe that the valve drains and closes properly.
9. Return the equipment to the desired readiness condition.
0016 016304 -3lank
0 0- / 0 b