TM 9-2320-360-10
Table 3-1. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
ENGINE CRANKS BUT WILL NOT START
Step 1.
Check if three DDEC circuit breakers have been tripped.
Reset DDEC circuit breaker(s) if they have been tripped.
Step 2.
Turn ENGINE switch to ON position. Check FUEL gage for quantity of fuel in tanks.
Add fuel as required.
Step 3.
Check if both fuel shutoff valves are in open position. If valves are
closed, fuel cannot get from right to left fuel tank.
Open valves if closed.
Step 4.
Check if fuel tank vent hoses are plugged. If vent hoses are
plugged, vacuum can be created inside fuel tank. Clean vent hoses
as required.
3-6 Change 1