Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
X6. NO POWER TO SINGGAR/FORCE XXI BATTLE COMMAND BRIGADE AND BELOW (FBCB)
(CONT)
(c)
Remove electrical distribution block cover from electrical distribution shelf.
(d)
Check circuit breaker (CB8) to see if it is tripped.
If circuit breaker (CB8) is tripped, push reset button in to reset.
If circuit breaker (CB8) trips again, notify Unit Maintenance.
Step (2) Check to see if SINGGAR/Force XXI Battle Command Brigade and Below (FBCB) has power.
If SINGGAR/FBCB does not have power, notify Unit Maintenance.
(a)
Position electrical distribution block cover on power distribution shelf.
(b)
Tighten wing screw on electrical distribution block cover.
(c)
Install wing screw in power distribution shelf.
Change 2
3-84.25