Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
x. SPECIAL PURPOSE KIT (CONT)
X5. NO POWER TO DRIVER VISUAL ENHANCEMENT (DVE) (CONT)
(d)
Check circuit breaker (CB6) to see if it is tripped.
If circuit breaker (CB6) is tripped, push reset button in to reset.
If circuit breaker (CB6) trips again, notify Unit Maintenance.
Step (2) Check to see if Driver Visual Enhancement (DVE) has power.
If DVE does not have power, notify Unit Maintenance.
(a)
Position electrical distribution block cover on power distribution shelf.
(b)
Tighten wing screw on electrical distribution block cover.
(c)
Install wing screw in power distribution shelf.
X6. NO POWER TO
SINGGAR/FORCE XXI BATTLE COMMAND BRIGADE AND BELOW (FBCB)
WARNING
Remove rings, bracelets, wristwatches, neck chains, and any other jewelry before
working around vehicle. Jewelry may catch on equipment or may short across an
electrical circuit. Failure to comply may result in serious injury or death to personnel.
Step 1. Check to see if circuit breaker (CB8) is tripped.
(a)
Remove wing screw from power distribution shelf.
(b)
Loosen wing screw on electrical distribution block cover.
Change 2